Page 167 - Modernfold Architectural Products
P. 167

Acousti-Seal  ENCORE  Automated Technical Data
                                           ®
                               ®
               10 22 26 (10650) Operable Partitions



               ACOUSTI-SEAL  ENCORE  AUTOMATED SERIES TECHNICAL DATA
                                    ®
                                                  ®
               PART 2 – PRODUCTS                                  formed steel with overlapped and welded
                                                                  corners for rigidity. Top channel is reinforced to
               2.1 MANUFACTURERS, PRODUCTS, AND OPERATION         support suspension system components. Frame
               A.  Manufacturers: Subject to compliance with      is designed so that full vertical edges of panels
                  requirements, provide product by the following:  are of formed steel and provide concealed
                  1. Modernfold, Inc.                             protection of the edges of the panel skin.
               B.  Products: Subject to compliance with the    B. Panel Skin Options:
                 requirements, provide the following product:     1.  Roll-formed steel wrapping around panel
                  1.  Acousti-Seal  Encore  Automated - #20 Track   edge. Panel skins shall be lock formed and
                                      ®
                               ®
                    System electrically operated continuously       welded directly to the frame for unitized
                    hinged operable partition.                      construction. Acoustical ratings of panels with
                                                                    this construction:
               2.2 OPERATION                                           a. 52 STC
               A.  Acousti-Seal  Encore  Automated - #20 Track         b. 54 STC
                                    ®
                            ®
                  System: Series of continuously hinged flat panels,         c. 56 STC
                  electrically operated, top supported with    C.  Hinges for Pass Doors, and Pocket Doors shall be
                  operable floor seals and automatic top seals.   (select one):
               B. Final Closure (select one):                     1.  Full leaf butt hinges, attached directly to panel
                  1.  Electric expanding jamb sealing to panel      frame with welded hinge anchor plates within
                    edge. Manual closures or side seal closures not   panel to further support hinge mounting to
                    permitted. Floor track not required or permitted.  frame. Lifetime Warranty on hinges. Hinges
                  2.  Electric expanding jamb sealing to panel edge   mounted into panel edge or vertical astragal
                    with “Presto Automation Package”. Manual        are not acceptable.
                                                                        ®
                    closures or side seal closures not permitted.      2.  SOSS  Invisible laminated hinge with antifriction
                    Floor track not required or permitted.  (For    segments mounted between each heat
                    complete specification see Presto Package       treated link. Hinge to be attached directly
                    brochure Form #2513)                            to panel frame. Welded internal hinge
                  3.  Remote closure with expanding panel edge      bracket shall support the hinge and allow for
                    with removable crank. Floor track not required   adjustment of hinge plates. Concealed hinges
                    or permitted.                                   mounted into panel edge or vertical astragal
               C.  Partition shall be operated by two push button   are not acceptable.
                  control stations wired in series and located on   D.  Panel Trim: No vertical or horizontal trim required
                  opposite sides of the partition. Control stations   or allowed on edges of panels; minimal groove
                  shall be activated by key switch at stack end   appearance at panel joints.
                  of partition. Motor unit shall be reversible,   E. Panel Weight:
                  continuous duty, and class A insulated. Motor      1. Steel Skin
                  unit shall have NEMA MG 1 service factor, high         a. 52 STC – 8.2 lbs./square foot
                  starting torque, thermal overload protection,         b. 54 STC – 9.5 lbs./square foot
                  and open/drip proof enclosure. Motor assembly         c. 56 STC – 11.9 lbs./square foot
                  shall have wiring compliant with NFPA 70, 24 volt
                  controls, compliant with UL 508A, and speed   2.4 PANEL FINISHES
                  of 28 feet/minute. The drive unit motor shall be   A. Panel face finish shall be (select as required):
                  equipped with outboard limit switches to prevent      1.  Reinforced vinyl with woven backing weighing
                  over-extension. A positive chain drive attached   not less than 21 ounces per lineal yard.
                  to the lead panel shall pull the partition across      2.  Reinforced heavy duty vinyl with woven backing
                  the opening. Cable, belt, or other friction type   weighing not less than 30 ounces per lineal yard.
                  drives will not be accepted.                    3.  Acoustical, non-woven needle punch carpet,
               D. Electric motor shall be (select one):             with fused fibers to prevent unraveling or fray
                  1. 208/230-volt, 3-phase, 1-1/2 HP, 4.5/4.3 FLA   of material.
                  2. 460-volt, 3-phase, 1-1/2 HP, 2.2 FLA         4.  Wall covering and upholstery fabric with
                  3. 208/230-volt, 3-phase, 3 HP, 9/8.4 FLA         surface treatment to resist stains.
                  4. 460-volt, 3-phase, 3 HP, 2 FLA               5.  Customer’s own material (subject to factory
                                                                    approval).
               2.3 PANEL CONSTRUCTION                             6. Full height steel markerboard work surface.
               A.  Nominal 4-1/4-inch (108 mm) thick panels in      7.  Full height 1/4-inch (6.35 mm) natural cork
                  manufacturer’s standard 51-inch (1295 mm)         tackboard with vinyl or fabric covering.
                  widths. All panel horizontal and vertical framing      8. Uncovered for field finishing.
                  members fabricated from minimum 16-gage         9. Primed for field finishing.


               6               Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.