Page 131 - Fundamental of Engineering Design
P. 131

Example 2

      A plate of  100mm x 10mm thick is under force of 120kN. Calculate the

         length of the plate needed if the welded connection is using a class 400

         MPa electrode.


      For class 400MPa electrode, allowable shear stress 120MPa. Since the
         plate is more than 6.4 mm, the maximum filet weld size is 1.6mm less than

         the thickness of the plate.


      P = Sv x 0.707 x size x length


      120x 10 =120x10 x0.707 x (0.01-0.0016)x2L
                                  6
                   3
      L = 0.0842m =84.2mm.




      Example 3


      Determine the safe load for the butt weld that connects two plates of 100mm

         thick and 200mm long if the allowable shear stress is 140MPa.


      P = (S)(t)(l)


                           6
          = 140 x 10 x 0.2 x 0.1
          = 2.8 MN.                                                                                                                 131