Page 210 - Towards A Sustainable Future , Phase 3 2025, E-Book_Neat
P. 210

a  refrigerator  in  the  pantry.  The  well-lit  warehouse  space  Phase 2 - Monitoring Implementation:
            suggests considerable lighting-related power consumption.  Following the identification of key energy-consuming devices,
                                                                 a  student-developed  current  monitoring  system  would  be
            The  second  floor,  dedicated  to  administrative  operations,  deployed to collect real-time consumption data. This custom
            represents  another  central  energy  consumption  point  monitoring  solution  would  be  installed  on  selected  high-
            with  its  fully  air-conditioned  office  space.  The  third  floor's  consumption  devices  to  track  their  energy  usage  patterns
            meeting  room,  also  climate-controlled,  adds  to  the  cooling  over a predetermined period (between 18th December 2024
            requirements. Five air-conditioning compressors serving these  and 8th January 2025). The monitoring system would provide
            upper levels indicate substantial energy demand for climate  detailed insights into:
            control, which likely contributes significantly to the facility's  • Daily consumption patterns of selected devices
            high electrical bills. The environmental review suggests that  • Peak currents
            the primary contributors to the high electrical consumption  • Usage duration and frequency
            were  the  facility's  major  appliances  and  climate  control
            systems.  The  five  air-conditioning  compressors  serving  the  Phase 3 - Analysis and Recommendations:
            upper levels likely represent the most significant power draw,  The final phase would focus on analysing the collected data
            followed by the high-energy appliances on the ground floor,  to:
            including the water heater, washer, dryer, and refrigerator.  • Compare actual device consumption against manufacturer
                                                                     specifications
            This  essential  operational  equipment  requires  a  detailed  • Identify inefficient equipment or systems
            energy  audit  to  identify  potential  inefficiencies  and
            opportunities  for energy optimisation.  Understanding  these  Based on this analysis, the project would deliver:
            devices' usage patterns and efficiency ratings would be crucial  • A consumption profile of selected devices
            in developing targeted strategies for reducing overall energy  • Provide practical recommendations for the necessary
            consumption and associated costs.                       improvement in consumption, leading to cost-saving


            Objectives                                           Environmental Aspects
            This  project's  primary  objective  is  to  investigate  Wen  The  following  were  some  observations  from  the  initial  site
            Hong's  electrical  energy  consumption  patterns  through  a  visit:
            systematic  three-phase  approach:  site  survey,  monitoring
            implementation,  and  data  analysis  to  reduce  consumption  Energy Consumption:
            and cut associated carbon emissions.                 The facility demonstrates significant electrical energy usage
                                                                 across  all  three  floors,  primarily  from  lighting  and  cooling
            Phase 1 - Site Survey:                               systems.  The  LED  lighting  installation  throughout  the
            The initial phase involved a detailed site survey of Wen Hong's  building represents a positive energy-efficient choice, though
            three-level  facility  to  identify  and  document  high-energy-  continuous operation across three floors still contributes to
            consuming devices commonly found in commercial buildings.  the overall power consumption. The five inverter-equipped air
            This included but was not limited to air-conditioning systems,  conditioning compressors servicing levels 2 and 3 constitute
            lighting infrastructure, office equipment, and any specialised  a portion of the building's energy consumption, albeit using
            security system infrastructure. Additionally, the survey would  relatively efficient inverter technology.
            examine  current  operational  practices  and  behaviours  that
            might contribute to elevated energy consumption.

                                                              208