Page 44 - QR CIMAR LASER SCREED
P. 44

TROUBLESHOOTING GUIDE

PROBLEM                              CHECK
Linear actuator will not move
                                     Manual/Auto Switch is where you want it
                                     All cords for laser control are plugged in and tight.
                                     Transmitter is on & rotating
                                     Key switch is turned and e-stop switch is up
                                     Battery is charged.
                                     Linear actuator packard connectors are plugged in

Machine will not hold grade          Side-Side oscillation is locked
                                     Too close to laser transmitter.
                                     Laser is reflecting off of glass and bouncing back
                                     Laser receiver is slipping down
                                     Re-set up the plow
                                     Machine level
                                     Subgrade bad
                                     Pulling too much concrete with plow
                                     Receivers picking up flashing light from elsewhere on jobsite

Machine is not sealing the concrete  Check vibrator speed
                                     Attack angle of head (tie rod setting)
                                     Remove counterweights from rear of machine

Hard to turn traveling in the forward Turn Traction Assist off
direction

Vibrator does not turn on while Vibrator switch on

screeding                            Quick disconnect hoses are connected properly.

Machine does not stop when           Operator presence switch on left handlebar working
operator releases handles