Page 133 - QR KLINDEX EXPANDER850AT-RXt
P. 133

TROUBLESHOOTING

11.1.1	 Error display                                   –	press the key     to display information regard-

Following any appliance faults, follow the indications  ing the appliance control status when any fault has
provided below to display error history:
–	switch on the appliance control, the letters "ALM"    occurred (for example, "oC")

  flash

                                                        –	press the key     to go back to parameter U2-01

                                                        –	press the key     followed by key  to move

–	press the key     until the monitor screen is dis-    to parameter U3-01
  played

                                                        –	press the key     followed by key  to scroll

–	press the key     to display the meter settings       through the parameters from U3-01 to U3-05
  screen

                                                        –	press the key     to display the information re-

–	press the key     followed by key  to move            lating to the selected parameter followed by the key

to parameter U2-01                                      to go back to the display with the parameters.

                                                        Contact Klindex and report the error messages of
                                                        parameters U2-01 to U2-08 and U3-01 to U3-05. This
                                                        information is needed in order to identify the cause
                                                        of the any faults.

                                                        Description of parameters

–	press the key     followed by key  to scroll           Parameters      Description
                                                              U2-01      Current error
through the parameters from U2-01 to U2-08                    U2-02      Previous error
                                                              U2-03      Frequency reference at previous error
                                                              U2-04      Output frequency at previous error
                                                              U2-05      Output current at previous error
                                                              U2-06      Motor speed at previous error
                                                              U2-07      Output voltage at previous error
                                                              U2-08      Bus DC voltage at previous error
                                                                         Last 5 errors
                                                        U3-01 to U3-05

www.klindex.com - Made in Italy                                                                                 43
   128   129   130   131   132   133   134   135   136   137   138