Page 132 - QR KLINDEX EXPANDER850AT-RXt
P. 132

TROUBLESHOOTING

11	 Troubleshooting                                      3	 Up arrow key
                                                                 To scroll upwards and select parameters, set-
11.1	 Inverter                                                   ting values, etc.

An inverter is installed inside the electric panel (see  4	 LO/RE light
the section "Electric panel (internal view)" on page             It activates when the local actuation control is
12), equipped with a display on which the error codes            active.
appear in the event of a fault or malfunction.
                                                         5	 LO/RE key
d  NO                                                            To switch actuation control between the oper-
   Tampering inside the inverter or altering                     ator (LOCAL) and the control circuit terminals
   its settings. The appliance is supplied with                  (REMOTE).
   the parameters pre-set for correct oper-                      NOTE: the LOCAL / REMOTE key works during
   ation. Klindex S.r.l. is not liable for any                   stoppages in automatic mode. If the operator
   damage caused by failure to observe the                       unintentionally switches from REMOTE to LO-
   above.                                                        CAL, set o2-01 (LOCAL/REMOTE Key Function
                                                                 Selection) to "0" (disabled) to disable the LOCAL
f  ELECTRICAL HAZARD                                             / REMOTE key.

   – The appliance operates on electricity               6	 RESET key
     therefore pay careful attention there is                    To move the cursor to the right.
     a risk of electric shocks which may be                      To reset the control after a fault.
     fatal.
                                                         7	 RUN light
   – Only qualified technicians are author-                      It activates when the motor is running.
     ised to act on the inverter.
                                                         8	 RUN key
12  3 45                                                         To switch on the appliance control.

                        STOP                             9	 Arrow down key
6 7 8 9 10 11                                                    To scroll downwards and select parameters,
                                                                 setting values, etc.

                                                         10	STOP key
                                                                 To stop the appliance control.
                                                                 NOTE: to stop the priority circuit. A quick stop
                                                                 mode can be used by pressing the STOP key
                                                                 when the unit detects a hazard. This works even
                                                                 if the appliance control is in operation using a
                                                                 multifunction input terminal (REMOTE is set).
                                                                 To prevent a stop using the STOP key, set o2-02
                                                                 (STOP Key Function Selection) to 0 (disabled).

                                                         11	ENTER key
                                                                 To select all the modes, parameters, settings,
                                                                 etc.
                                                                 To move from one screen to the next.

1	 Display
        To view the frequency, parameter number, etc

2	 ESC key
        To go back to the previous menu.

42 www.klindex.com - Made in Italy
   127   128   129   130   131   132   133   134   135   136   137