Page 62 - QR KLINDEX EXPANDER850AT-RXt
P. 62

TROUBLESHOOTING

11.1.2	 Error codes

Code            Description                            Checks to run

                DC Bus Undervoltage                    Make sure that the appliance is powered correctly (see section “Connecting
                                                       to the power socket”)
                Control Power Supply Voltage Fault     Check that the power supply cable is intact
                                                       Check the three-phase fuses (see section “Electric panel (internal view)”)
                Safe Disable Signal Input
                                                       Make sure that the appliance is powered correctly (see section “Connecting
                Overcurrent                            to the power socket”)
                Motor overload                         Make sure that all the emergency buttons are released and are working
                Driver overload                        correctly (pressed, contact open: released, contact closed)
                                                       Manual: make sure that the left/right dial is set to the centre
                Heatsink Overheat                      Radio controlled: make sure that the left/right dial is set to the centre

                             Undervoltage              Restart the appliance
                                                       If the error persists, replace the motor
If the problem persists, contact Klindex
For any other error message, contact Klindex           Make sure that the appliance is powered correctly (see section “Connecting
                                                       to the power socket”)
                                                       With the appliance off, make sure that the planetary rotates freely when its
                                                       planets are turned by hand (refer to the maintenance section)
                                                       Make sure that tools are used which are suitable for the flooring. If nec-
                                                       essary, use tools with a greater number of sectors to increase the contact
                                                       surface
                                                       If working at a low speed, increase the rotation speed of the planetary (to
                                                       approx. 4-6)
                                                       Use the weight kit in the central position
                                                       Insert the front wheel and lift the appliance until the tools just touch the
                                                       ground
                                                       Check operation of the cooling fans

                                                       Appliance disconnected from the power network. This message appears a
                                                       few moments after the appliance has been switched off. The inverter does
                                                       not switch off immediately but stays on to display this message for a few
                                                       seconds and then switches off completely

11.2	 Possible faults and solutions                    Solution

 Fault                                                 Make sure that the appliance is powered correctly (see section "Connecting
                                                       to the power socket")
                "Grinding power ok" LED does not       Make sure that the LED is not damaged and that the connections are intact
                activate                               (see the wiring diagram supplied together with the appliance)

Electric panel                                         Check the fuses in position 11 and 12 of fuse holder 3 (see section "Electric
                                                       panel (internal view)")
                The auxiliary socket is not working    Check the transformer

                PLC ready light does not activate and  Check the fuses in position 7 and 8 of fuse holder 3 (see section "Electric
                the fans do not turn                   panel (internal view)")
                Will not turn on
                                                       Make sure the battery is charged
                Does not activate (NO VALID DATA)      Contact Klindex

Radio control                                          Make sure that the appliance is powered
                                                       Make sure the battery in the appliance is charged
                The battery status LED flashes twice   Make sure that the receiver is connected to the connector
                every 20 seconds                       Make sure that all pins of the receiver connector are intact

                The battery status LED flashes in an   Radio control battery depleted
                abnormal way
                                                       Contact Klindex and specify the number of flashes

For any other faults, contact Klindex

48 www.klindex.com - Made in Italy
   57   58   59   60   61   62   63   64   65   66   67