Page 57 - QR KLINDEX EXPANDER850AT-RXt
P. 57
MAINTENANCE
10 Maintenance 10.3 Clean appliance and radio
control
10.1 General information
d NO
l WARNINGS Using pressure washers or similar to clean
the appliance.
– Before performing any operation on the
appliance, make sure that the main dial Always clean the appliance and the radio control after
is set to “OFF” and the power cable is each use. Use a sponge with water and detergent.
disconnected.
10.4 Clean the electric panel filter
– Always use appropriate PPE as de-
scribed in section "Protective clothing" Clean the inside of the electric panel and the inverter
on page28. case filters with a vacuum cleaner once a day. If the
results are not satisfactory, replace the filter with an-
– If maintenance interventions are not other of the same size and features.
carried out as and when they are sched-
uled, the lifespan of the appliance may
be reduced and the risk of accidents
may increase.
– Maintenance interventions on the appli-
ance must only be carried out by suita-
bly trained technicians.
– If in any doubt or if you have any que-
ries regarding maintenance interven-
tions, contact the Klindex S.r.l. custom-
er support.
10.2 Maintenance schedule
INTERVENTIONS FREQUENCY l NOTICE
At the end of every If operating on steel-fibre reinforced
Clean the planetary and planets flooring, the filters are to be cleaned once
shift every hour of operation.
Check emergency buttons Daily
Check state of wear of the tools Daily 10.5 Check and change splash guard
Check that the tool holders are intact Daily
Check connections of pipes and cables Daily The appliance is equipped with a rubber strip which
Check state of operational wear of the wraps around the planetary and tools completely. It
electrical cables Daily serves to prevent any water spray during the grinding
Clean appliance and radio control operation and to ensure effective dust extraction.
Clean splash guard and filler necks Daily Every time the appliance is used, visually check that
Clean the electric panel filter Daily the splash guard is in a good condition, check that it is
Check warning labels Daily fully intact and sufficiently soft to ensure perfect ad-
Check planetary fastening to the frame Weekly herence to the floor.
Check bolt tightening Weekly Check that the extraction inlet is not clogged.
Check flexible joints Weekly
Check splash guard Weekly
Weekly
Grease planetary arm After the first 50
operating hours and
Grease reduction gear then every 100 hours
After the first 50
operating hours and
then every 100 hours
www.klindex.com - Made in Italy 43