Section 6 – Adjustments

              6.6.2 – Minimum Opening

              The minimum deck plate opening is controlled by the
              four sided cam (C) on the side of the row unit frame.


              1)  Minimum possible opening is 3/4" (19mm) at the
                 front and 15/16” (24mm) at the rear.
              2)  To adjust loosen the flange bolt (D) and rotate
                 the cam (C).
              3)  The four sided cams have numbers laser cut in
                 them.
                     a.  Larger Number = Larger deck plate
                        minimum opening.
                     b.  Smaller Number = Smaller deck plate
                        minimum opening.


             Checking Front Minimum Opening

             Insert tool ST-7 (F) in between the deck plates at the
             point where the curve at the front of the deck plate
             stops. Ensure that the text “Min_F” is between the
             deck plates. The deck plates should lightly touch tool
             ST-7 (F). If the deck plates are pushed open or a gap
             exists between the tool and the deck plates the
             minimum opening setting should be adjusted.

             Note: The front minimum opening is the critical
             measurement for correctly setting the deck plates and
             should be inspected periodically through the harvest
             season.






             Checking Rear Minimum Opening

             Insert tool ST-7 (G) in between the deck plates at the
             rear of the opening. Ensure that the text “Min_R” is
             between the deck plates. The deck plates should lightly
             touch tool ST-7 (G). The rear deck plate opening is not
             adjustable independent of the front opening.

             Note: The deck plate rear minimum opening does not
             need to be inspected on a regular basis. It requires
             inspection only if damage to the system is suspected
             or if conditions require changes to the maximum
             opening.