Page 105 - Catalogue - cuvettes and solid-state calibration standards
P. 105
UV/VIS/NIR photometric accuracy
As far as we are aware, the Superband standards are the only ones that enable verification of photometric
accuracy over the entire 200-3000nm UV/VIS/NIR range.
10 calibration points
Part Number Description Price
FF-SPB-0.04-10CP Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 1,893.68
FF-SPB-0.2-10CP Optical density 0.04AU (90% transmission). 10 calibration points 1,893.68
FF-SPB-0.3-10CP Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 1,893.68
FF-SPB-0.5-10CP Optical density 0.2AU (60% transmission). 10 calibration points 1,893.68
FF-SPB-1.0-10CP Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 1,893.68
FF-SPB-1.5-10CP Optical density 0.3AU (50% transmission). 10 calibration points 1,893.68
FF-SPB-2.0-10CP Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 1,893.68
FF-SPB-2.5-10CP Optical density 0.5AU (30% transmission). 10 calibration points 1,893.68
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Optical density 1.0AU (10% transmission). 10 calibration points
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Optical density 1.5AU (3% transmission). 10 calibration points
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Optical density 2.0AU (1% transmission). 10 calibration points
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Optical density 2.5AU (0.3% transmission). 10 calibration points
Complete calibration data
Part Number Description Price
FF-SPB-0.04-CCD Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 3,156.84
FF-SPB-0.2-CCD Optical density 0.04AU (90% transmission). Complete calibration data from 200-3300nm 3,156.84
FF-SPB-0.3-CCD Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 3,156.84
FF-SPB-0.5-CCD Optical density 0.2AU (60% transmission). Complete calibration data from 200-3300nm 3,156.84
FF-SPB-1.0-CCD Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 3,156.84
FF-SPB-1.5-CCD Optical density 0.3AU (50% transmission). Complete calibration data from 200-3300nm 3,156.84
FF-SPB-2.0-CCD Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm). 3,156.84
FF-SPB-2.5-CCD Optical density 0.5AU (30% transmission). Complete calibration data from 200-3300nm 3,156.84
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Specifications: Optical density 1.0AU (10% transmission). Complete calibration data from 200-3300nm
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Optical density 1.5AU (3% transmission). Complete calibration data from 200-3300nm
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Optical density 2.0AU (1% transmission). Complete calibration data from 200-3300nm
Superband calibration standard for UV/VIS/NIR photometric accuracy (200-3000nm).
Optical density 2.5AU (0.3% transmission). Complete calibration data from 200-3300nm
Optical density and transmission: please see the descriptions of the individual products shown above
Wavelength range: 200-3000nm - 10 calibration points (10CP types) complete data (CCD types)
External dimensions: 12.5 x 12.5 x 45.0mm
NIST-traceable
97
All prices are shown in Euro and are subject to VAT where applicable.