Page 23 - Genex EN76 Installation Manual - Issue 05.03.2020
P. 23
Issue: 03/12/2019
Use and positioning of frame spacers
Max. 2500 mm!
Aisle
Node point - Node point
Lower diagonal frame spacer
Double entry rows of racking will have a space between the two frames on either side of the rack.
This space is necessary to allow an overhang of the pallets and front to back clearance.
Each frame pair is connected via frame spacers. These are positioned at the node points of the
frame.
● One spacer at the bottom diagonal node point
● One spacer at the upper diagonal node point
● The lower spacer at the lowest diagonal always points away from the aisle!
● The first spacer is always mounted at the lowest node point where the first diagonals are
connected to each other!
● The last spacer is always mounted at the last node point, the connection point of the last
diagonal (optional with horizontal) is connected!
● A minimum of 2 spacers must be used for every frame.
● The maximum distance of 2500 mm must not be exceeded!
● If larger distances are required, additional spacers must be added.
Spacers are not positioned accurately at the node points, but at the nearest position above or below
the node points.
When specifying spacer levels, beam position must be considered.
EN76 Pallet Rack System | 23