51-2
                                     Heater and air conditioner- heater and air conditioner
                                                           8.     don’t make  the  liquid refrigrant enter
                                                                  into the eyes or contact the skin
                                                           If the liquid refrigerant enters  into the eyes or
                                                           contacts the skin.
                                                           (a).   Wash the contact part with a large amount
                                                                  of cold water.
                                                           Notice:
                                                           Don’t rub the eyes or skin.
                                                           (b).   Apply clean vaseline.
                                                           (c).   Please go to the hospital at once.


         9.     don’t heat up or place the tank body on the open fire.
         10.    don’t make it drop or hit it, and be careful during the movement.

                                                           11.    don’t operate the compressor  while
                                                                  there is not enough refrigrant in  the
                               wrong    right                     refrigeration system.
                                                           If there is not enough refrigerant in  the
                                                           refrigeration system, the lubrication of engine oil
                                                           will not be enough, the compressor may be burnt
                                                           out, please be careful to avoid this condition.
                                                           12.    don’t open  the high-pressure  pipeline
                                                                  when the compressor is operating
                                                           If the high-pressure valve is open, the refrigerant
                                                           will  flow backwards,  which may break  the
                                                           cylinder  body of the compressor;  therefore,  only
                                                           the low-pressure valve can be open and closed.
         13.    don’t fill too much refrigrant in the refrigeration system
         If too much refrigerant is filled, the heat radiation will be not enough, the economical efficiency of the
   51    fuel oil will be poor and the engine will be too hot.
         14.    don’t open the system when there are puddles or when it is raining.
         15.    the refrigeration system opened  shall be  covered or wraped  up  for sealing  in time  to
                prevent water vapour or foreign matters in the air from entering into it.
         16.    the refrigeration oil  shall be covered closely at any time and the trademark of the
                refrigeration oil shall be indicated, different trademarks of refrigeration oil can’t be used
                together to avoid reducing the quality or viscosity of the oil.
         17.    the reservoir must be installed at last while installing the refrigeration system.
         18.    supply refrigeration oil first for the system while replacing with new refrigrant and then
                fill into refrigrant.
         19.    the repair tools must be clean and dry, the installation and maintenance site must be clean.
         20.    the rubber  sealing materials  that are  used to make various sealing soft pads (washers)
                shall have good compatibility with the refrigerant.
         21.    the connection hose must be made of the materials that are specially used for refrigeration;
                nylon shall be used for the lining of connection hose that is applicable to r-134a.
         22.    the refrigerant must be discharged slowly to avoid discharging refrigeration oil together,
                and it can’t contact the lustrous metal surface.
         23.    don’t fill liquid refrigrant into the low-pressure end and don’t start the compressor while
                filling refrigrant into the high-pressure end.
         24.    don’t clean the condenser and evaporator with vapour, only cold water or compressed air
                can be used.
         25.    protect the vehicle with retaining washers or other things while repairing the refrigeration system.
         26.    don’t start the compressor before filling cooling medium into the refrigeration system.
         27.    if the compressor (used) shall be kept for a long period to avoid corrosion, discharge the
                air inside the compressor and fill refrigrant or dry nitrogen into it.







                                                                                                        Page 1094