Page 125 - Workshop Manual - Aumark (BJ1051)
P. 125
03-51
Maintenance Specifications-Propeller Shaft
1089 series models
Drive shaft assembly
Radial runout of drive shaft
Standard value 0.5 mm
Limit value 0.6 mm
Fit clearance between spline shaft
and splined hub Standard value 0.1 mm
Limit value 0.3 mm
Universal joint
Cross journal
Standard value 26.68 mm
Wear limit 0.10 mm
Cross to needle bearing clearance 0.016~0.071 mm
Universal joint fork to needle 0.15~0.40 mm
bearing clearance
03
Axial clearance of cross ≤ 0.25 mm