Page 306 - Workshop Manual - Aumark (BJ1051)
P. 306

04-162
                                                 Diagnosis-illumination

          Diagnostic Procedure


          1.     Checking combination switch

                                                    (a)     Check combination switch.

                                                          Resistances:

                                                                          Use a multimeter to   Specified
                                                          Condition
                                                                             connect pins        value
                                                       Turn light switch        5 - 1           > 1 MΩ
                                                            OFF                 8 - 1

   04                                                 Turn light switch ON      5 - 1            ≤ 2 Ω

                                                                                8 - 1





          Are check results normal?
          Yes > Repair or replace harnesses.
          No > Replace combination switch.





















































                                                                                                         Page 306
   301   302   303   304   305   306   307   308   309   310   311