Page 460 - Workshop Manual - Aumark (BJ1051)
P. 460
04-316
Diagnosis-power windows
(c) Measure resistances according to the values listed in the following table.
Use a multimeter
to connect Switch status Resistance
terminals
04
1 - 2 Right front window lift ≤ 2 Ω
3 - 5 Right front window lift ≤ 2 Ω
Right front window still (i.e. switch in natural
1 - 5 ≤ 2 Ω
position)
Right front window still (i.e. switch in natural
2 - 4 ≤ 2 Ω
position)
2 - 3 Right front window drop ≤ 2 Ω
4 - 5 Right front window drop ≤ 2 Ω
Are check results normal?
Yes > Reconnect connector of right front door electric glass switch.
If the symptom persists, replace right front door electric glass switch.
No > Replace right front door electric glass switch.