Page 460 - Workshop Manual - Aumark (BJ1051)
P. 460

04-316
                                                      Diagnosis-power windows
















               (c)    Measure resistances according to the values listed in the following table.
                 Use a multimeter
                     to connect                         Switch status                        Resistance
                     terminals
  04
                        1 - 2                        Right front window lift                    ≤ 2 Ω

                        3 - 5                        Right front window lift                    ≤ 2 Ω
                                            Right front window still (i.e. switch in natural
                        1 - 5                                                                   ≤ 2 Ω
                                                           position)
                                            Right front window still (i.e. switch in natural
                        2 - 4                                                                   ≤ 2 Ω
                                                           position)
                        2 - 3                       Right front window drop                     ≤ 2 Ω

                        4 - 5                       Right front window drop                     ≤ 2 Ω

               Are check results normal?
               Yes >   Reconnect connector of right front door electric glass switch.
                      If the symptom persists, replace right front door electric glass switch.
               No >    Replace right front door electric glass switch.











































                                                                                                         Page 460
   455   456   457   458   459   460   461   462   463   464   465