Page 486 - Workshop Manual - Aumark (BJ1051)
P. 486
04-342
Diagnosis- combination meter
(b) Use a multimeter to measure resistance
between connector pin 3 of speedometer
sensor C048 and connector pin 13 of
combination meter B033.
Resistance: ≤2Ω
Is check result normal?
04 Yes > Replace combination meter assembly.
No > Repair signal line between connector pin 3 of speedometer sensor C048 and connector pin
13 of combination meter B033.
Page 486