Page 486 - Workshop Manual - Aumark (BJ1051)
P. 486

04-342
                                                    Diagnosis- combination meter

                                                                (b)     Use a multimeter to measure resistance
                                                                        between connector pin 3 of speedometer
                                                                        sensor C048 and connector pin 13 of
                                                                        combination meter B033.
                                                                        Resistance: ≤2Ω








               Is check result normal?
   04          Yes >   Replace combination meter assembly.
               No >    Repair signal line between connector pin 3 of speedometer sensor C048 and connector pin
                      13 of combination meter B033.