Page 61 - YORAM RUDY BOOK FINAL
P. 61

P. 61

















































        Figure 2.40. Alternans: AP and CaT clamp protocols. A. AP (top), CaT (middle) and I        Ca,L  (bottom)
        during alternans at 4Hz pacing rate. B. AP clamp with long (black) or short (gray) AP. Despite
        AP clamp (top), CaT alternans persist (bottom). C. CaT clamp (bottom) to its small (gray) or large
        (black) waveform eliminates AP alternans (top). D. I    Ca,L  clamp (bottom) does not eliminate AP (top)
        or CaT (middle) alternans. From Livshitz and Rudy [42] with permission.





                           2.11.  Regulation of Cellular Calcium Cycling and
                                        Electrophysiological Processes



               Calcium handling and electrophysiological processes in cardiac myocytes are subject to
        regulation by several regulatory pathways, notably the Ca /calmodulin-dependent protein kinase
                                                                       2+
        (CaMKII) pathway and the ß-adrenergic cascade. The Ca subsystem and electrophysiology

        subsystem of the cell are tightly coupled. Therefore, regulation of one subsystem affects the
        other subsystem through nonlinear and complex interactions. Thus, regulation of CaT affects
        the AP and vice versa. The Regulatory processes exert direct effects on components of each

        subsystem, which then affect the other subsystem indirectly through complex interactions. The
        complexity of this dual system requires mathematical modeling for understanding mechanisms
        and predicting outcomes of various interventions. Here, we provide examples of simulating the
        CaMKII pathway and ß-adrenergic cascade.
   56   57   58   59   60   61   62   63   64   65   66