The clean oil storage tank should be periodically drained and thoroughly cleaned. If
                       the area where the storage tanks are located is dusty, it may be desirable to install a
                       filter in the tank’s vent line. If water contamination is persistent or excessive, a
                       desiccant breather may be required.

                       Storage and handling of oils can be found in TI 1000-0099L. The following conditions
                       apply to oil used for Jenbacher 3 Series generator sets:

                              •  Proper storage in buildings (recommended)
                              •  The room must be clean and dry keep the temperature and air humidity
                                 constant
                              •  Make sure opened drums are properly sealed again
                              •  Avoid storage in direct sunlight and under -5 °C
                              •  Protect against rain and snow
                              •  Store barrels horizontally not vertically, with the bung hole at the bottom
                              •  Make sure opened drums are properly sealed again (no water must be
                                 allowed to get into the oil)
                              •  If stored for extended periods, carefully roll the drums once every 2 months
                                 to mix the oil

               Oil Samples

                       Oil sampling should be done in accordance with TI 1000-0112. Always take oil samples
                       with the engine running completely normally under load. When sampling, it is
                       imperative that the operator drain off approx. 0.3 l of oil before taking the actual
                       sample. After taking the oil sample, send it to a laboratory together with the sampling
                       report sheet without delay. The time
                       between taking the sample and its arrival at the laboratory must not exceed 5 days.
                       There are no exceptions!

                       When taking a sample, it is a must that the correct data is recorded and sent to the lab.
                       Often, these analysis results are used to make assessments for troubleshooting
                       purposes. If the information is skewed, then the troubleshooting based on these
                       samples becomes inaccurate. See example below.