Page 49 - PIGNAT catalogue 2020 GB_092020
P. 49

PUMPS BENCH




          BEP/2000  CENTRIFUGAL PUMPS STUDY


                                                            ➢    Study of the characteristics of a centrifugal pump and coupling
                                                                 two pumps in series / parallel

                                                            Study of the two self-contained centrifugal pumps in suction operation
                                                                 Plot the characteristic graph at various speeds
                                                                 Observe cavitation
                                                                 Determine yield electrical consumption/hydraulic power

                                                            Study of the pump coupling methods
                                                                 Coupling in series
                                                                 Coupling in parallel

                                                            Study a motor pump assembly in suction operation (optional)
                                                                 Determination of characteristic TDH (total dynamic head) graphs against
                                                                 flow rate
                                                                 Determination of yields (electrical consumption/motor torque/hydraulic



                                                                 General specifications        Instrumentation

                                                                                       • Vacuum Gauges.
                                                            •  150 L PE tank with removable lid and   • Manometer.
                                                    www.pignat.com
                                                  www.pignat.com
                                                             draining valve.
                     Photo, with moto-pump option             •  SS  centrifugal  pump:  measurement   • 2 flowmeters.
                                                                                       • Vacuum gauges.
                                                                                       • Manometer.
                                                             of the power consumed and variable
                                                             speed.

                                                            •  SS centrifugal pump and transparent
                      A  security  system  with  low  flow  en-  flange.
                      sures  smooth operation  and  long life                               200 - 400 V   Water   Drainage
                      of the pumps                          •  Serial coupling selection valve.   3ϕ - 50/60 Hz   500 L / h
                                                                                            Dim: 210 x 70 x 225 cm  -  250 kg
                      A  transparent  shroud  on  the  second
                      pump   allows   to   visualize   the
                      cavitation.





                                 The design of this unit allows:
                                      The study of a closed loop operation            16
                                      The study of pumps (6 and 11) individually coupled
                                      in series or in parallel.                          17          14   15

                                 The arrangement of the valves (15, 16 and 17) ensures the   8        13
             Other versions      coupling.                                        7                         12
                                                                                         5          10

        BEP/3000                 All gauges (5, 7, 10 and 12) mounted on the suction and   6  P1           P2  11
        Study of centrifugal pumps   discharge pumps are used to determine the HMT.          4   9
        Pressure  and  temperature
        influence.               The suction throttle, allows to highlight the phenomenon of   18
                                 cavitation at the pump 11.
                                                                            EAU
                                 The pump 6 is provided with a drive controller and a power   2       1
                                 meter for determining, for various speeds of operation, the   LL  3
                                 characteristic of the pump and the power consumption.











                             Fluids & fluidization                                                            49