Page 55 - PIGNAT catalogue 2020 GB_092020
P. 55

SOLID—LIQUID FLUIDIZATION




                                              FLS/3000  SOLID-LIQUID FLUIDIZATION


                                              ➢     Study the fluidization with water of a bed of glass beads

                                              Fluidization study
                                                    Determine experimentally the minimum fluidization speed
                                                    Study the expansion of the bed
                                                    Analyze pressure drops as a function of water flow rate

                                              Study the influence of parameters on fluidization
                                                    Column diameter
                                                    Glass bead diameter and density
                                                       General specifications              Instrumentation
                                                                                 •  2 flowmeters.
                                              •  Tank with removable lid.        •  Piezometric  tube,  a  hand  pump  for  the
                                                                                  pressure setting, draining valve.
                                              •  SS centrifugal pump.
                                                                                              In option
                                              •  Glass column, L = 1 m, packed with         Ø 6   •  Electronic differential pressure transmitter.
                                                mm glass beads.                  •  A control panel with a touch screen.

                                              •  Glass column, L = 1 m, packed with         Ø 6
                   In option supervision        mm glass beads.

                                                    www.pignat.com
                                                  www.pignat.com
                                              •  Glass column, L = 1 m, packed with         Ø 3
                                                mm glass beads.

                                              •  Set of valves: column selection and draining.   100 - 240 V   Water
                                                                                                          500 L / h
                                                                                                 1ϕ - 50/60 Hz
                                                                                          Dim: 160 x 90 x 190 cm  -  150 kg


                                       COMBINED FLUIDIZATION          FLM/2000


                                           ➢    Liquid-Solid  and Gas-Solid fluidization study

                                            Theoretical and experimental study of fluidization
                                                       Porosity and expansion of bed, bubbling
               Theoretically determination of the minimum fluidization velocity: Kozeny-Carman and Ergun equation
                                            Experimentally determine the minimum fluidization speed

                                             Study the influence of parameters on fluidization

                                                                     Bed characteristics:
                                                              Particle diameter and density
                                                                  Bed porosity and height.
                                                                    Fluid characteristics:
                                                                 Fluid flow rate and nature


                   General specifications     •  Solid-liquid  fluidization:  glass  column,  evacuation
                                               jar,  support:  glass  perforated  plate,  two  pressure
        •  Compressed  air  feeding  circuit:  general  isolating   ports,  quick-closing  clamp,  recovery  filter  at  the
          valve, pressure reducing valve isolating valve.   outlet.

        •  Gas-solid fluidization: glass column, evacuation jar,   Instrumentation
          glass  fritted  support,  two  pressure  ports,  quick-  •  Air flowmeter.
          closing clamp.                      •  Water flowmeter.

        •  Differential  manometer  of  liquid  column,  filling
          valve, draining valve and scale.

                                                                      Water
        •  Water feeding circuit:  general  isolating valve, float   2000 L / h   2 bar max
          flowmeter   with setting valve.
                                                            Dim: 105 x 55 x 175 cm  -  60 kg

        54                                                            Fluids & fluidization
   50   51   52   53   54   55   56   57   58   59   60