Page 75 - Vessel Sanitation Program 2018 Operations Manual
P. 75

VSP 2018 Operations Manual



                                            The free residual HALOGEN and pH measured by the
                                            HALOGEN/pH analyzer must be accurate to within 0.2 mg/L
                                            (ppm) of the free residual HALOGEN and 0.2 of the pH as
                                            measured by the manual test.

                                            Calibration is required at the beginning of bunkering or production
                                            and each time bunkering or production is restarted.

                              5.2.1.2.5     Construction (06)
                                            HALOGEN and pH analyzer-chart recorders used on bunker water
                                            systems must be constructed and installed according to the
                                            manufacturer’s guidelines.

                              5.2.1.2.6     Data Logger
                                            Electronic data loggers with CERTIFIED DATA SECURITY
                                            FEATURES may be used in lieu of chart recorders.

                                            If electronic data loggers are used, written documentation from the
                                            data logger manufacturer, such as a letter or instruction manual,
                                            must be provided to verify that the features are secure.

                              5.2.1.2.7     Halogen Injection (08)
                                            Water samples for HALOGEN and pH testing must be obtained
                                            from a sample cock and/or a HALOGEN analyzer probe located
                                            on the bunker or production water line at least 3 meters (10 feet)
                                            after the HALOGEN injection point and before the storage tank.


                                            A static mixer may be used to reduce the distance between the
                                            HALOGEN injection point and the sample cock or HALOGEN
                                            analyzer sample point. If used, the mixer must be installed per the
                                            manufacturer’s recommendations. A copy of all manufacturers’
                                            literature for installation, operation, and maintenance must be
                                            maintained.


                              5.2.1.2.8     Tank Sample
                                            In the event of EQUIPMENT failure, bunker or production
                                            water HALOGEN samples may also be taken from previously
                                            empty POTABLE WATER TANKS.

















                                                    5.0 Potable Water; 46