                   5.3        Potable Water System

                       5.3.1   Potable Water Tanks

                          5.3.1.1    Protection


                              5.3.1.1.1     Potable Water Tank Walls (07 C)
                                            POTABLE WATER TANKS must not share a common wall with
                                            the hull of the vessel or with tanks or piping containing nonpotable
                                            water or other liquids.


                              5.3.1.1.2     Nonpotable Piping (08)
                                            Piping systems carrying SEWAGE or other nonpotable liquids
                                            must not pass through POTABLE WATER TANKS. Minimize the
                                            use of nonpotable lines above POTABLE WATER TANKS.
                                            Nonpotable lines above POTABLE WATER TANKS must not
                                            have any mechanical couplings.


                                            For SCUPPER lines, factory assembled transition fittings for steel
                                            to plastic pipes are allowed when manufactured per American
                                            Society for Testing and Materials (ASTM) F1973 or equivalent
                                            standard.

                              5.3.1.1.3     Coatings (08)
                                            Interior coatings on POTABLE WATER TANKS must be
                                            APPROVED for POTABLE WATER contact by a certification
                                            organization. Follow all manufacturers’ recommendations for
                                            application, drying, and curing.

                                            The following must be maintained on board for the tank coatings
                                            used:
                                                •  Written documentation of approval from the certification
                                                   organization (independent of the coating manufacturer).
                                                •  Manufacturers’ recommendations for application, drying,
                                                   and curing.
                                                •  Written documentation that the manufacturers’
                                                   recommendations have been followed for application,
                                                   drying, and curing.

                          5.3.1.2    Tank Construction


                              5.3.1.2.1     Identification (08)
                                            POTABLE WATER TANKS must be identified with a number
                                            and the words “POTABLE WATER” in letters at least
                                            13 millimeters (0.5 inch) high.