                   5.6        Microbiologic Monitoring

                       5.6.1   Sampling and Analysis

                          5.6.1.1    Methodology


                              5.6.1.1.1     Samples (06)
                                            A minimum of four POTABLE WATER samples per month must
                                            be  collected and analyzed for the presence of E. coli. Samples
                                            must be collected from the forward, aft, upper, and lower decks of
                                            the vessel.

                                            Sample sites must be changed each month ensure effectively
                                            monitoring of all of the POTABLE WATER distribution system.

                                            Follow-up sampling must be conducted for each positive test
                                            result.


                                            Microbiological samples from ice machines and POTABLE
                                            WATER storage tanks do not count toward the monthly
                                            routine distribution system monitoring.

                              5.6.1.1.2     Analysis (06)
                                            Samples must be analyzed using a method accepted in Standard
                                            Methods for the Examination of Water and Wastewater or
                                            international Environmental Protection Agency (EPA)
                                            APPROVED equivalent. Test kits,  incubators, and associated
                                            EQUIPMENT must be operated and  maintained in accordance
                                            with the manufacturers’ specifications.

                          5.6.1.2    Records


                              5.6.1.2.1     Records (06)
                                            Sample results must be maintained onboard the vessel for at least
                                            12 months and must be available for review during inspections.

                   5.7        Water Distribution System Protection

                       5.7.1   Cross-connection Control

                          5.7.1.1    Program

                              5.7.1.1.1     Cross-Connections (07 C)
                                            The POTABLE WATER distribution system must be maintained
                                            free of CROSS-CONNECTIONS.