Page 93 - Vessel Sanitation Program 2018 Operations Manual
P. 93

VSP 2018 Operations Manual



                          6.2.1.2    In Port

                              6.2.1.2.1     Drained or Switched to Recirculation (10)
                                            Before arriving to a port or HARBOR, the RWF must be drained
                                            before the vessel reaches the 20-kilometer (12-mile) mark or any
                                            point of land-based discharge as detailed in section 6.2.1.1.1 and it
                                            must remain empty while in port or at anchor.


                                            OR

                                            The RECREATIONAL SEAWATER filling system must be shut
                                            off 20 kilometers (12 miles) before reaching the nearest land or
                                            land-based discharge point, and a recirculation system must be
                                            used with appropriate filtration and halogenation systems.


                              6.2.1.2.2     Halogen and pH (09 C)
                                            When switching from flow-through operations to recirculation
                                            operations, the RWF must be closed until the free residual
                                            HALOGEN and pH levels are within the acceptable limits of this
                                            manual. The sample must be taken from the body of the RWF, not
                                            from the pump room.

                                            While the RWF is closed, batch HALOGEN and pH control
                                            chemicals may be used to obtain ADEQUATE free HALOGEN
                                            residuals and pH levels in a more-timely manner. Sufficient
                                            time should be allowed before opening the RWF for use to
                                            ensure proper mixing of batch chemicals.

                   6.3        Recirculating RWFs
                              (See individual sections for additional requirements for whirlpools and SPA
                              POOLS. See Annex 13.8 for requirements for BABY-ONLY WATER
                              FACILITIES.)

                       6.3.1   Operation

                          6.3.1.1    Fill Level and Turnover Rates (10)
                                     For RWF with skim gutters, the fill level of the RWF must be to the skim
                                     gutter level.

















                                        6.0 Recreational Water Facilities (RWFs); 64