Page 56 - Vessel Sanitation Program 2018 Construction Guidelines
P. 56

VSP 2018 Construction Guidelines



















































                       14.1.3   Cleanout Ports
                                Install cleanout ports in the direct exhaust ducts of the ventilation systems
                                between the top of the warewashing machine and the hood system or
                                DECKHEAD.

                       14.1.4   Drip Trays
                                Provide ACCESSIBLE and REMOVABLE condensate DRIP TRAYS in
                                warewashing machine ventilation ducts. A dedicated drainage pipe from the
                                DRIP TRAYS to a GUTTERWAY or a DECK DRAIN is also acceptable.

                   14.2  Cooking and Hot-Holding Equipment

                       14.2.1   Cooking Equipment
                                Install hood or canopy systems above cooking equipment in accordance with
                                safety of life-at-sea (SOLAS) requirements to ensure they remove excess steam
                                and grease-laden vapors and prevent condensate from collecting on surfaces.






                                                             40
   51   52   53   54   55   56   57   58   59   60   61