                   8.5    Counter-Mounted Equipment
                          Seal counter-mounted equipment, unless PORTABLE, to the countertop or mount it
                          on legs.

                       8.5.1    Leg Length
                                Leg length depends on the horizontal distance of the table top under the
                                equipment from either end to the farthest point requiring cleaning (see table
                                below).

                                 Horizontal Distance (Depth)       Equipment Leg Length
                                 More than 750 millimeters         At least 150 millimeters
                                 (30 inches)                       (6 inches)
                                 500 to 750 millimeters            At least 100 millimeters
                                 (20 to 30 inches)                 (4 inches)
                                 75 to 500 millimeters             At least 75 millimeters
                                 (3 to 20 inches)                  (3 inches)
                                 Less than 75 millimeters          50 millimeters
                                 (3 inches)                        (2 inches)

               9.0  Fasteners and Requirements for Securing and Sealing
               Equipment


                   9.1    Food-Contact Surfaces

                       9.1.1    Attach
                                Attach all FOOD-CONTACT SURFACES or connections from FOOD-
                                CONTACT SURFACES to adjacent splash zones to ensure a seamless COVED
                                corner.