Page 98 - Vessel Sanitation Program 2018 Construction Guidelines
P. 98

VSP 2018 Construction Guidelines



                          24.2.2.3      Alarm
                                        An alarm system that sounds when the diverter valve directs
                                        SANITARY SEAWATER or POTABLE WATER from the heat
                                        exchanger.

               25.0  Recreational Water Facilities Water Source


                   25.1  Filling System
                          Provide a filling system that allows for the filling of each RECREATIONAL
                          WATER FACILITY with SANITARY SEAWATER or POTABLE WATER.

                          For a compensation or make-up tank supplied with POTABLE water, an overflow
                          line located below the fill line and at least twice the diameter of the fill line is an
                          acceptable method of BACKFLOW protection as long as the overflow line discharges
                          to the wastewater system through an indirect connection. If make-up water is
                          introduced into the RECREATIONAL WATER FACILITY directly, the water should
                          be at the same level of HALOGENATION and PH as the RWF before entering the
                          RECREATIONAL WATER FACILITY.

                          Avoid BLIND LINES in the water systems of recreational water facilities.

                   25.2  Compensation or Make-Up Tank
                          Where make-up water is required to replace water loss due to splashing, carry out,
                          and other volume loss, install an appropriately designed compensation or make-up
                          tank to ensure that ADEQUATE chemical balance can be maintained.

                   25.3  Combining Recreational Water Facilities
                          No more than two similar RECREATIONAL WATER FACILITIES may be
                          combined.

                          CHILDREN’S POOLS and BABY-ONLY WATER FACILITIES must not be
                          combined with  any other type of RWFs.

                   25.4  Independent Manual Testing
                          When combining RECREATIONAL WATER FACILITIES, provisions must be
                          made for independent manual water testing within the mechanical room for each
                          RECREATIONAL WATER FACILITY.

                   25.5  Independent Slide Recreational Water Facility and Adult Swimming Pool
                          An independent slide RECREATIONAL WATER FACILITY and an adult
                          SWIMMING POOL may be combined provided that the water volume added to the
                          slide and the slide pump capacity are sufficient to maintain the TURNOVER rate as
                          shown in section 29.10. Any other  combinations of RECREATIONAL WATER
                          FACILITIES will be decided on a case-by-case basis during the plan review.






                                                             82