ACCUWEIGH

ACCUWEIGH R-220

1. Move SW1-1, “Type 2” is displayed
2. Press T.Save three times, “Ad 1” is displayed
3. Remove Weight, press ON/ZERO
4. Place 20 lbs, press U.P.Save
5. Place 40 lbs, press U.P.Save
6. Press MODE, Move SW1-1

ACCUWEIGH DKS-3002

1. Clear scale, press ON and Units key at same time, then release
2. Press ON/ZERO, display will show 0
3. Place 2kg on scale, press and hold UNITS key then press ON/ZERO
4. Display will show CAL
5. Press UNITS key 2 more times, display will flash “CAL” then 8888, then 2kg

ACCUWEIGH DP-8100

1. Press cal switch on bottom of scale
2. Press and hold N/G and press ON/<0>
3. Press N/G
4. Empty scale, press T
5. Load ½ cap and press T
6. Load full cap and press T
7. Press OFF
8. Press ON

ACCUWEIGH DPI-500
(SAME AS TRANSCELL TI-500)

ACCUWEIGH DSY-1100

1. Turn sale over and short J22 and J23 on circuit board
2. Follow procedure for DP-8100

ACCUWEIGH PPC-100/101/200W

1. Short test jumpers on PCB
2. Press and hold N/G and press ON/<0>
3. Press N/G until 2 or 3 is displayed above mode (2= zero and Span, 3=Zero/Mid/full)
4. Clear Platform, press T
5. Place ½ cap and press T
6. Place full cap and press T
7. Press OFF then ON