RICE LAKE 920i FIRMWARE UPDATING

1.Disconnect power to the 920i.
2.Connect the PC serial port to port 2 of the 920i. Connection must be made at 38400 bps.
3.Open the indicator enclosure and place a jumper across the SW1 boot mode pins (see
Figure 2-6 on page 12).
4.Power up the 920i. The indicator will stall at the diagnostic monitor.
5.Click on the Update Indicator button to download the new software. When the download
begins, the following messages are shown:
Loading…
System Diagnostic Monitor v1.14
$
?
$
?
$KNIX
$SYSLOAD
6.When the download is complete, the indicator display shows the following messages:
$DONE
$BOOT
Loading…
7.The indicator resets and goes to weigh mode.
8.Disconnect power to the indicator. Remove the jumper from across the SW1 boot mode pins
and place it on a single pin.
9.Power up the indicator and reload iRev 4 and iRite files as necessary.

DOWNLOADING A SECTION OF IREV CONFIGURATION

If you need to change settings for only one section of the configuration file for the 920i then you can
download just that section by doing the following:

1. Connect to Indicator
2. Upload current indicator configuration or select “yes” to overwrite iRev’s current configuration
3. Make changes to section of configuration
4. Select “Communication” and then “Download Current Display”