Page 88 - Practical Technology 2025
P. 88

nd
               Clinical Pharmacy-Pharm D        Level Three        2  Semester       2024/2025      Pharmaceutical Technology (PT 607)


               Problem 2

               A Particle size analysis was carried out on a pharmaceutical powder using the

               sieve method, the following data were obtained
                   •  Calculate mean particle diameter
                   •  Draw a cumulative % frequency under and over size

                                  Sieve number                     Weight retained
                                 Passed/retained
                                      100/120                              0.81
                                      80/100                              23.60
                                       60/80                              52.30
                                       40/60                              13.75
                                       20/40                               4.72
                                       10/20                               0.82



               Solution

                 Mid-point of         Weight
                  size range         retained
                                    Frequency
                                        (n)


                      110               0.81
                       90              23.60
                       70              52.30
                       50              13.75
                       30               4.72
                       15               0.82


























                                                           86
   83   84   85   86   87   88   89   90   91   92   93