FAN-PEDIA                                                    SPECIAL CONSTRUCTION

 Published by
 Twin City Fan & Blower                                                     NOMINALLY LEAK-TIGHT
 ©2017   TCF.COM


 Continuous Weld      GENERAL INFORMATION
 > Weld locations vary by model
                      A fan generally cannot be constructed to be totally leak tight.  Hence
 Gasketing            the term “Nominally Leak Tight” is used. This type of construction is
                      used to reduce leakage to within acceptable levels decided upon with
 > Double gaskets required  the customer. Fans are tested at the shop with a Soap Bubble Test to
                      check for leaks.
 Shaft Seal           Fan  leakage  refers  to  air  (or  other  gas  mixture)  either  leaking  into
                      the fan housing or out of the fan housing. Leakage in or out depends
 Drain                on air pressure. When the air (or gas mixture) mixes with hazardous
 > Pipe Coupling Type with Plug  contaminants, excessive leakage can be dangerous. Excessive leakage
                      can waste energy, be an environmental or safety hazard, damage fan
                      bearings or create excessive noise.

                      - Fan Construction
                            > Arrangements 1, 8 and 9 only
                            > Solid drive side on housing (no drive plates)
                            > Not recommended for applications over 600 F
                                                                                                               o
                            > Split housings not recommended
                             > Bolted connections must have close centered hole patterns (3”
                                to 4” centers) Includes:  inlet and outlet flanges, access doors,
                                cover plates, inlet funnels, split housings, etc.

                      - Gasketing
                             > Use on all connections: inlet/outlet flanges, funnel, inlet  plate,
                                access doors, split housing, etc.
                             > Split housings require centering plate to seal open areas by
                                shaft seals and inlet funnel or plate

                      - Shaft Seals (Fan Shaft - do not use shaft sleeve & cap)
                             > Lip type
                             > Stuffing Box (Graphoil) type
                             > Double Ring Mechanical type (Double Carbon Ring)









                                                                                                                                                   95