                                  GENERAL INFORMATION
 Continuous Weld
 > Weld locations vary            A regenerative thermal oxidizer (RTO) is an industrial process that
 > See engineering standard E1-14  destroys  air  pollutants  emitted  from  process  exhaust.  These  gas
                                  streams are usually produced by industrial process ventilation, i.e.
 Seal Weld                        paint booths, printing, and paper mills. Fans are tested at the shop
 > Weld locations vary            with a Soap Bubble Test to check for leaks.
 > See engineering standard E1-14
                                  - Fan Construction
 Gasketing                              > Solid drive side on housing (no drive plates)
 > Double gaskets required               > Bolted connections must have close centered hole patterns
                                            (3” to 4” centers) Includes:  inlet and outlet flanges, access
                                            doors, cover plates, inlet funnels, split housings, etc.
 Shaft Seal                             > Not recommended for applications over 600 F
                                                                                                                          o
                                         > Dampers (if required) must have stuffing boxes
 Pedestal Foot Gussets
                                  - Gasketing
                                        > Use silicone sponge & silicone caulk
 Centering Plates                       > Use on all connections: inlet/outlet flanges, funnel, inlet
                                        plate, access doors, split housing, etc.
                                        > If constructed with a split housing, centering plates are
                                        required to seal open areas by shaft seals and inlet funnel or
                                        inlet plate

                                  - Shaft Seals
                                         > Friction type
                                         > Single Carbon Ring type
                                         > Commercially available carbon ring or others seal

                                  - Special Requirements (sales to specify)
                                         > Pedestal – Concrete requirements
                                         > Fan Base – Construction based on how fan will be mounted
                                         in field
                                         > Fan Operation (VFD, Cycling, Bake Out conditions)