Turning tools \ Technical introduction – turning - ISO turning

                       selection of chip breaker – positive chip breaker
                       steel materials

           selecting the correct chip breaker depends on the infeed (ap), the cutting conditions and the feed values to be achieved. the aim is to achieve optimal chip breakage

         with a defi ned infeed. the following graphs illustrate the different chip breakers and their applications.
                               M                                                     P
             16                                                    16
            a  ( mm )  p  6,3       FP                           a  ( mm )  p  6,3 10    FP3
             10
              4                                                    4
             2,5                                                  2,5  FP3
             1,6                                                  1,6
              1                                                    1
                  FP
             0,63                                                 0,63
             0,4                                                  0,4                     0,112
             0,25                                                 0,25
                                    18°                                                        6°
             0,16                                                 0,16
             0,1                                                  0,1
              0,025 0,04  0,063 0,1 0,16 0,25 0,4 0,63  1  1,6 2,5  0,025 0,04  0,063 0,1 0,16 0,25 0,4 0,63  1  1,6 2,5
                                f ( mm )                                             f ( mm )



                               P                                                     P
             16                                                    16
            a  ( mm )  p  6,3       FU                           a  ( mm )  p  6,3 10    MP
             10
              4                                                    4   MP
             2,5  FU                                              2,5
             1,6                                                  1,6
              1                                                    1
             0,63                                                 0,63
                                             1,09
             0,4                                                  0,4                            0,1
                                           0,08
             0,25                               30°               0,25
             0,16                   15°                           0,16                   12°
             0,1                                                  0,1
              0,025 0,04  0,063 0,1 0,16 0,25 0,4 0,63  1  1,6 2,5  0,025 0,04  0,063 0,1 0,16 0,25 0,4 0,63  1  1,6 2,5
                                f ( mm )                                             f ( mm )



                               P                                                     P
             16                                                    16
            a  ( mm )  p  6,3      MP3                           a  ( mm )  p  6,3 10    MU
             10
              4                                                    4     MU
             2,5  MP3                                             2,5
             1,6                                                  1,6
              1                                                    1
             0,63                                                 0,63
             0,4                           0,13                   0,4                                0,17
             0,25                                                 0,25                        0,17
                                    19°                                                  15°
             0,16                                                 0,16                                22°
                                                                                           2°
             0,1                                                  0,1
              0,025 0,04  0,063 0,1 0,16 0,25 0,4 0,63  1  1,6 2,5  0,025 0,04  0,063 0,1 0,16 0,25 0,4 0,63  1  1,6 2,5
                                f ( mm )                                             f ( mm )


                               P
             16
            a  ( mm )  p  6,3      MW
             10
              4
             2,5
             1,6
                    MW
              1
             0,63
             0,4
             0,25                     15° 18°
             0,16
             0,1
              0,025 0,04  0,063 0,1 0,16 0,25 0,4 0,63  1  1,6 2,5
                                f ( mm )
       Source: Hahn+Kolb Werkzeuge GmbH