Page 16 - 5937_2019_07_Cennik_angielski_v5
P. 16

OTHER INSULATIONS
                EPS SUPERPODDASZE (ATTIC) EPS



              SUPERPODDASZE (ATTIC) EPS boards are applied      board is placed between rafters as a self-moun-
              as thermal insulation in sloping roofs. Thanks to   ting (expanding) waste-free insulation element.
              special longitudinal or perpendicular notches, the                                                                    In addition to EPS, Termo Organika also offers other thermal insulation materials.




                                                                                                                                    POLYURETHANE BOARDS termPIR





                                                                                                                                    These boards are characterised by a very advantageous
                                                                                                                                    thermal conductivity coefficient (λ – lambda) and high

              Installation of insulations between the rafters with the use of SUPERPODDASZE (attic) boards – suggestions:           resistance to damage and biological corrosion.
              4   measure the distances between the rafters,    4   boards are placed between the rafters, slightly
              4   prepare the appropriate number of boards for the   compressed or bent,                                              POLYURETHANE BOARDS termPIR
                  required dimension between the rafters,       4   board mounting starts with the lowermost roof
              4   boards have to be 3% wider than the dimension     level,                                                           KEY PROPERTIES                                    INTENDED FOR INSULATING
                  between the rafters to get the effect of self-  4   board pieces which have been cut should be used
                  mounting (expansion) of the boards between the    by placing them parallelly between the rafters in                  perfect thermal protection of building             flat roofs,
                  rafters,                                          successive layers.                                              4                                                 4
                                                                                                                                        partitions,                                   4   sloping roofs,
                                                                                                                                    4   very high resistance to damage,               4   sheet pile walls, foundation walls,
                                                                                                                                    4   low weight of the insulation,                 4   floorings,
                GROOVED EPS                                                                                                         4   water resistance,                             4   agricultural infrastructure and industrial
                                                                                                                                    4   stable dimensions,                                and warehouse buildings.
                                                                                                                                    4   milled edges,
              Grooved EPS for frame walls. It is provided with   ble air circulation. This provides excellent thermal               4   resistance to fungi and microorganisms,
              specially  shaped  surface  on  which  grooves  are   insulation  with  simultaneous  ventilation  of  the            4   fast installation reducing labour costs,
              made in parallel to the shorter board edge to ena-  space under the cover.                                            4   ease and safety during installation work (PIR
                                                                                                                                        does not require personal protective equipment,
                                                                                                                                        e.g. dust masks),
                                                                                                                                    4   safe to the ozone layer (PIR is free                               *   depends on cladding type
               15 mm                 50 mm  50 mm                                                                                       of chlorofluorocarbons).                                            and thickness
                                                                                                                                                                                                        λ   –   declared thermal conductivity
                                                                                                                                                                                                         D
                                                                                                                                                                                                            coefficient lambda [W/(m·K)].
                                                                                                                                        λ  – from 0.022* W/(m·K)
                 On special request, grooves with other dimensions can be                                                               D
                 made.
                                                                                                                                    Board dimension: 1200 x 600 mm

                                                                                                                                     Thickness, mm  20  30  40  50  60  70  80  90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
                                                                                                                                     No. of boards
                                                                                                                                     in pkg.     24  16  12  10  10  7  6  6  5  5  5  4   4  4  3   3  3   3  3  2   2  2   2  2
                                                                                                                                     Board area
                                                                                                                                     m²/pkg.    17.28 11.52 8.64 7.20 7.20 5.04 4.32 4.32 3.60 3.60 3.60 2.88 2.88 2.88 2.16 2.16 2.16 2.16 2.16 1.44 1.44 1.44 1.44 1.44
                                                                                                                                     Package volume
                                                                                                                                                                                                                                            PIR AND XPS
                                                                                                                                     m³/pkg.    0.35 0.35 0.35 0.36 0.43 0.35 0.35 0.39 0.36 0.40 0.43 0.37 0.40 0.43 0.35 0.37 0.39 0.41 0.43 0.30 0.32 0.33 0.35 0.36










                                            EXTERNAL THERMAL INSULATION COMPOSITE SYSTEM                                                                   EPS    PLASTERS    PAINTS    ADHESIVES                               17
   11   12   13   14   15   16   17   18   19   20   21