So, or, Total line current, Current, I lags voltage, V by 15° Power factor = cos ϕ = cos 15° = 0.96 lagging Magnitude of current, I = 20.68 A Supply voltage, V = 230 V Power consumed, P = VI cos ϕ = 230 × 20.68 × 0.96 = 4566 W