440                                                               Fiber Optic Communications




                                0.1                                          Ch.1
                             Amp (arb. unit)  0.05





                                 0
                                  –200  –100    0     100    200   300    400    500
                                                       Time (ps)

                                0.1                                          Ch.2
                             Amp (arb. unit)  0.05





                                 0
                                  –200  –100    0     100    200   300    400    500
                                                       Time (ps)

            Figure 10.10  Input pulses for channels 1 and 2. The following parameters were assumed: P  = 8mW, T  = 50 ps,
                                                                              peak      FWHM
                                                                    −1
                                                    3
                                         2
            channel spacing = 50 GHz,  =−10 ps /km,  = 0ps /km,  = 2.43 W −1  km , fiber loss = 0.2 dB/km, and span length
                                              3
                                 2
            80 km.
                                0.1                                          Ch.1
                             Amp (arb. unit)  0.05




                                 0
                                  –200  –100    0     100    200   300    400    500
                                                       Time (ps)
                                0.1                                          Ch.2
                             Amp (arb. unit)  0.05





                                 0
                                  –200  –100    0     100    200   300    400    500
                                                       Time (ps)

                    Figure 10.11  Output pulses for channels 1 and 2. Parameters are the same as those of Fig. 10.10.
   454   455   456   457   458   459   460   461   462   463   464