Page 106 - GuardII+ Series 4208 Platform PD User Manual
P. 106
Appendix
Address Range Data
49600 to 49663 Phase C Pair 6 2D Data
49900 to 49963 Phase A Pair 7 2D Data
50200 to 50263 Phase B Pair 8 2D Data
50500 to 50563 Phase C Pair 9 2D Data
50800 to 50863 Phase A Pair 10 2D Data
51100 to 51163 Phase B Pair 11 2D Data
51400 to 51463 Phase C Pair 12 2D Data
48200 to 51563 2D Data for the Alert range
48200 to 48263 Phase A Pair 1 2D Data
48500 to 48563 Phase B Pair 2 2D Data
48800 to 48863 Phase C Pair 3 2D Data
49100 to 49163 Phase A Pair 4 2D Data
49400 to 49463 Phase B Pair 5 2D Data
49700 to 49763 Phase C Pair 6 2D Data
50000 to 50063 Phase A Pair 7 2D Data
50300 to 50363 Phase B Pair 8 2D Data
50600 to 50663 Phase C Pair 9 2D Data
50900 to 50963 Phase A Pair 10 2D Data
51200 to 51263 Phase B Pair 11 2D Data
51500 to 51563 Phase C Pair 12 2D Data
8.2.8. Hydro PD Card Measurement Details
Address Data Notes
12000 User Range Phase A Pair 1 The year of the last measurement
Year Expressed in 4 digits (i.e., 2019)
12001 User Range Phase A Pair 1 The month of the last measurement
Month 1 = January … 12 = December
12002 User Range Phase A Pair 1 The day of the month of the last measurement
Day
12003 User Range Phase A Pair 1 The hour of the last measurement
Hour Expressed in 24-hour mode (0-23)
12004 User Range Phase A Pair 1 The minute of the last measurement
Minute 0-59
12005 User Range Phase A Pair 1 The second of the last measurement
Second 0-59
12006 Measurement Type This indicates the measurement range where:
0 = User Range
1 = Auto Range
2 = Alert Range
12007 User Range Phase A Pair 1 The number of AC cycles in the last
AC Cycles measurement
12008 User Range Phase A Pair 1 The AC Max Value – for Iris Power use only
AC Max Value
98