Page 101 - GuardII+ Series 4208 Platform PD User Manual
P. 101

Appendix




                   Address     Data                            Notes
                   12012       User Range Phase A              The measurement status is a sum of values
                                   Measurement Status              that indicate the status and quality of the
                                                                   measurement.
                                                               Refer to Section 8.3.1 for details on how to use
                                                                   this register.
                   12300 to    User Range, Phase B Pair 2      Same as User Range Phase A Pair 1 data
                       12312       data
                   12600 to    User Range, Phase C Pair 3      Same as User Range Phase A Pair 1 data
                       12612       data
                   12100 to    Auto Range, Phase A Pair 1      Same as User Range Phase A Pair 1 data
                       12112       data
                   12400 to    Auto Range, Phase B Pair 2      Same as User Range Phase A Pair 1 data
                       12412       data
                   12700 to    Auto Range, Phase C Pair 3      Same as User Range Phase A Pair 1 data
                       12712       data
                   12200 to    Alert Range, Phase A Pair 1     Same as User Range Phase A Pair 1 data
                       12212       data
                   12500 to    Alert Range, Phase B Pair 2     Same as User Range Phase A Pair 1 data
                       12512       data
                   12800 to    Alert Range, Phase C Pair 3     Same as User Range Phase A Pair 1 data
                       12812       data

              8.2.5.  Bus PD Card Summary Numbers

                        All PD Summary numbers are float values occupying two 16-bit fields.

                   Address     Data                           Notes
                   12014       Phase A Pair 1 Machine         Data is from the User Range
                                   +NQN Value
                   12016       Phase A Pair 1 Machine         Data is from the User Range
                                   –NQN Value
                   12018       Phase A Pair 1 Machine         Data is from the User Range
                                   +QM Value
                   12020       Phase A Pair 1 Machine         Data is from the User Range
                                   –QM Value
                   12022       Phase A Pair 1 System          Data is from the User Range
                                   +NQN Value
                   12024       Phase A Pair 1 System          Data is from the User Range
                                   –NQN Value
                   12026       Phase A Pair 1 System          Data is from the User Range
                                   +QM Value
                   12028       Phase A Pair 1 System          Data is from the User Range
                                   –QM Value
                   12314 to    User Range Phase B Pair 2      Same as User Range Phase A Pair 1 data
                   12328           Summary numbers