Page 165 - Microsoft Word - 2_Inch_Drain_Adapter_PDS_2016_01_05
P. 165

DURO-GRIP  INSTA-STIK  PROFESSIONAL INSULATION ADHESIVE
                                                      ™
                                         ™
            ROOF PENETRATIONS/DRAINS            STEEL DECK APPLICATIONS             WARRANTY
            Additional adhesive is required     With the edge of the insulation     Duro-Last will warrant the adhesion
            around all roof penetrations and    board centered over an upper        of INSTA-STIK to specified
            drains.                             flange for normal application rate,   compatible materials and
                                                apply a 3/4" - 1" (19.05 - 25.4 mm)   substrates for a period of fifteen
            ROOF DECK APPLICATIONS              bead of INSTA-STIK on the first full
            Use a parapet wall or gutter as a   upper flange nearest the edge of    (15) years provided installation is in
                                                                                    accordance with Duro-Last specs.
            straight edge guide when            the insulation board. Continue to
            dispensing the first bead of INSTA-  apply 3/4“ - 1" (19.05 - 25.4 mm)   TECHNICAL SERVICES
            STIK. Under the normal application   beads on upper flanges as          Roofing Technical Support is
            rate, place the first bead 3" (76.2   specified. See Table 2. Place the   available from Duro-Last. Contact
            mm) within the outside edge of the   insulation board onto the beads    Engineering Services for
            insulation board to be attached.    within 5 minutes and walk on the    information.
            Apply 3 additional parallel beads   boards to spread the INSTA-STIK
            approximately 12“ (304.8 mm) apart   for maximum contact.
            so that the fourth bead is 3" (76.2   Additional walkings are required
            mm) within the opposite edge of the   every 5-7 minutes until the
            insulation board. The result is 4   insulation boards are firmly
            equidistant parallel beads (16 lineal   attached, usually 15 - 45 minutes.
            feet (5 m) for each 4' (1.2 m) square
            (4'×4' [1.2×1.2 m]) insulation board.



                                                1
                                APPLICATION RATE  – BASED ON 3/4 – 1 INCH (19 – 25 MM) DIAMETER BEAD
               Building Height    Parapet Wall Height   Perimeter Area Width
                                                                                    Spacing Between Beads
                  feet (m)            inch (mm)            feet (m)
                                                                             Perimeter Area         Field Area
                                                                             inch (mm) o.c.       inch (mm) o.c.
                                    0 – 24 (0 – 610)        4 (1.3)             6 (152)             12 (305)
                  0 – 20 (6)
                                      25+ (635+)            4 (1.3)             12 (305)            12 (305)
                                    0 – 24 (0 – 610)        8 (2.4)             6 (152)             12 (305)
               21 – 40 (6 – 12)   25 – 48 (635 – 1219)      4 (1.3)             6 (152)             12 (305)
                                     49+ (1245+)            4 (1.3)             12 (305)            12 (305)
                                    0 – 24 (0 – 610)       12 (3.7)             6 (152)             12 (305)
               41 – 70 (13 – 21)   25 – 48 (635 – 1219)     8 (2.4)             6 (152)             12 (305)
                                     49+ (1245+)            4 (1.3)             6 (152)             12 (305)
                                    0 – 24 (0 – 610)       12 (3.7)             6 (152)              9 (228)
              71 – 100 (22 – 31)   25 – 48 (635 – 1219)    12 (3.7)             6 (152)             12 (305)
                                     49+ (1245+)           12 (3.7)             6 (152)             12 (305)
                                    0 – 24 (0 – 610)       12 (3.7)             6 (152)              9 (228)
              101 – 200 (31 – 61)   25 – 48 (635 – 1219)   12 (3.7)             6 (152)              9 (228)
                                     49+ (1245+)           12 (3.7)             6 (152)             12 (305)
             201 – 300 (61 – 91.5)    Any Height           16 (4.9)             6 (152)              9 (228)
             Greater than 300 (91.5)   Any Height            NA                 6 (152)              6 (152)
           1
            – Coverage is approximately 500 – 800 lineal feet at 3/4 – 1 inch (19.1 – 25.4 mm) bead of adhesive per 23 lb (10 kg) tank of INSTA-STIK
            – Chemical temperature below 50 degrees F (10 degrees C) could result in reduced coverage rates
            – Agitating the cylinder of INSTA-STIK for at least 15 seconds is required for proper yield and performance











               www.duro-last.com                           4 of 4                                 800-248-0280
                                      Duro-Last and “World’s Best Roof” are registered trademarks owned by Duro-Last, Inc.
                                                  Created: 01/01/2009 Revised: 12/30/2015