            DESCRIPTION:
                     ®
            Duro-Last  Vapor Barrier is a self-adhesive vapor
            barrier membrane composed of SBS modified
            bitumen adhesive on the bottom surface and a tri-
            laminated woven polyethylene on the top surface. A
            silicone release film covers the self-adhesive on the
            bottom surface.
            Duro-Last Vapor Barrier can be used within a Duro-
                ®
            Last  roof system to minimize vapor transmission.
            Duro-Last recommends the use of vapor barriers,
            however it is the responsibility of the Duro-Last
            contractor of record to ensure that all applicable
            specifications, building codes, regulations and
            ordinances are complied with and followed. A          Figure 1. Duro-Last Vapor Barrier as temporary roof
            roofing professional, such as a consultant or
            architect, should be utilized for correct roof system   The installing contractor is responsible for following
            design prior to installing any roof system.           applicable building, plumbing and electrical codes.
            Duro-Last Vapor Barrier can provide a durable,        Elastocol Stick primer is not required when the roof
            walkable, temporary surface that protects the         system is mechanically fastened or when the
            decking for up to 4 months until a Duro-Last system   substrate is a steel deck. When used within an
            can be installed (See Figure 1). Duro-Last does not   adhered roof system, the following substrates will
            warrant the water-tightness of temporary roofs.       require the use of Elastocol Stick primer prior to
            Temporary roofs do not carry any type of warranty     installing the Duro-Last Vapor Barrier:
            and must only be used at the discretion of a roofing    Structural Concrete (poured in place or precast)
            consultant or architect.                                Gypsum (poured in place or precast)
            BENEFITS                                                Lightweight Concrete (insulating or cellular)
              Meets IECC air barrier requirements for              Wood (Plywood, OSB or Lumber)
               mechanically fastened roof systems                   Cement Block/Masonry
              Quick release film                                 APPROVED DIRECT-CONTACT ASSEMBLIES
              Self-sealing                                       The following membrane assemblies are approved
              Temporarily protects against inclement weather     for direct contact with Duro-Last Vapor Barrier. All
              Slip resistant                                     other assemblies must be separated from the Duro-
              Substrate board not required for most              Last Vapor Barrier by any Duro-Last slip sheet,
               applications.                                      insulation or cover board.         ®
                                                                                ®
              100% UV protection for up to 4 months                Duro-Fleece  and Duro-Fleece Plus
              Puncture resistant                                    o Adhered directly to Duro-Last Vapor Barrier
                                                                      with Duro-Fleece Membrane Adhesive or Duro-
              No primer required on steel decks or within            Fleece CR-20 Membrane Adhesive (Splatter).
               mechanically fastened roof systems.                  Duro-Last, Duro-Tuff  and Duro-Last EV
                                                                                       ®
              Ideal for mechanically fastened or adhered roof       o Adhered directly to Duro-Last Vapor Barrier
               systems                                                with SB IV Adhesive.
              Highly resistant to work crew traffic              WB II Adhesive is not allowed.
            ACCEPTABLE SUBSTRATES:                                FACTORY MUTUAL REQUIREMENTS
            Prior to installation of the Duro-Last Vapor Barrier,   Factory Mutual projects that require Duro-Last Vapor
            the substrate must be smooth and level without        Barrier will require an increase in the preliminary
            significant surface irregularities or depressions. It   attachment of insulation and/or cover boards
            must be clean, dry and free of grease, dust and       underneath mechanically fastened roof systems.
            loose debris. Do not apply to wet or damp surfaces.   Each board must be fastened at a rate of one
            Concrete and gypsum decks must be cured prior to      fastener and plate per two square feet. Corner and
            installation.                                         perimeter enhancements are not required for
                                                                  preliminary attachment.

             www.duro-last.com                              1 of 2                                800-248-0280
                         Duro-Last, Duro-Guard, Duro-Fleece, Duro-Fleece Plus, Duro-Tuff and “World’s Best Roof” are registered marks owned by Duro-Last, Inc.
                                               Created: 01/15/2014 Revised: 05/11/2015, 03/08/2016
   234   235   236   237   238   239   240   241   242   243   244