ELECTRICAL INSTALLATION                                    Fig. 1                               1




                        Product                     Page


          Plug-In AC Power Kit (PK00.PAC)              6



          Hard-Wired AC Power Kit (PK00.HAC)           6            Fig. 1a                 Fig. 1b
                                                                        2
          Multi-AC Power Kit (PK00.MAC)                7                 3                    5a


                                                                                                    5 5
         A    DC VERSIONS (PWRX & STANDARD

              BATTERY); Fig. 1                                                               INSTALL BATTERY

        1.  Remove CONTROL BOX COVER (1). Fig. 1.                                                   4
                                                                                                            CR-P2
        2.  Feed the SENSOR CABLES (2) through the top of
           CONTROL BOX (3). Fig. 1a.
                                                                                             STANDARD
                                                                    Fig. 1c                  BATTERY
        3.  Insert BATTERY (4) into BATTERY HOLDER (5),  make
           sure the shape of the BATTERY (4) follows the  shape
           of the BATTERY HOLDER (5) and terminal  end is                                6
           inserted first. Fig. 1b.
                                                                                            5a
        4.  Insert the BATTERY CONNECTOR (5a) for the  Standard                                            PWRX
           Battery or PWRX Battery Pack through  side GROMMET (6)
           as shown.  Fig. 1c.
        5.  Connect SOLENOID CABLE (7) and BATTERY
           CONNECTOR (5a) to SENSOR CABLES (2). Place                                            5a
           Standard Battery or PWRX Battery Pack into  Housing.
           Fig. 1d.
        6.  Replace CONTROL BOX COVER (1). Tighten cover            Fig. 1d
           screws firmly.


                                                                                            STANDARD       PWRX
                                                                                             BATTERY



                                                                     2      7





         CAUTION: Use only American Standard supplied
         transformers and cable sets. Using non-AS supplied              5a
         cables, or cutting, splicing or modifying any components
         will void the warranty.












                                                           5                                        M965612 Rev. 1.8 (12/17)