Page 259 - METRO CENTER PDF BINDER 1_Neat
P. 259
ELECTRICAL INSTALLATION Fig. 1 1
Product Page
Plug-In AC Power Kit (PK00.PAC) 6
Hard-Wired AC Power Kit (PK00.HAC) 6 Fig. 1a Fig. 1b
2
Multi-AC Power Kit (PK00.MAC) 7 3 5a
5 5
A DC VERSIONS (PWRX & STANDARD
BATTERY); Fig. 1 INSTALL BATTERY
1. Remove CONTROL BOX COVER (1). Fig. 1. 4
CR-P2
2. Feed the SENSOR CABLES (2) through the top of
CONTROL BOX (3). Fig. 1a.
STANDARD
Fig. 1c BATTERY
3. Insert BATTERY (4) into BATTERY HOLDER (5), make
sure the shape of the BATTERY (4) follows the shape
of the BATTERY HOLDER (5) and terminal end is 6
inserted first. Fig. 1b.
5a
4. Insert the BATTERY CONNECTOR (5a) for the Standard PWRX
Battery or PWRX Battery Pack through side GROMMET (6)
as shown. Fig. 1c.
5. Connect SOLENOID CABLE (7) and BATTERY
CONNECTOR (5a) to SENSOR CABLES (2). Place 5a
Standard Battery or PWRX Battery Pack into Housing.
Fig. 1d.
6. Replace CONTROL BOX COVER (1). Tighten cover Fig. 1d
screws firmly.
STANDARD PWRX
BATTERY
2 7
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied 5a
cables, or cutting, splicing or modifying any components
will void the warranty.
5 M965612 Rev. 1.8 (12/17)