Page 31 - B8773-AEW-XX-XX-PP-A-0001_[P1]_Contractors Manual
P. 31

2.5.2 Suspended Ceilings                                       Suitable MDF pattresses will need to be laid in the tiles
                                                               where needed, and the ceiling grid may then require
The customer area, together with all back of                   additional suspension wires to cope with this extra weight.
house areas which are visible to customers at
the counter, are to be finished with the same                  Where this rhythm clashes with existing fixed
suspended ceiling specification. The tiles and                 building features, or the position of the oven
grid will be sprayed to RAL 7037 Dusty Grey prior              extract hood, etc, then guidance must be
to delivery (Domino’s special). In back of house               sought from the Domino’s project manager.
areas not visible to the customer, white tiles can
be used as an alternative.                                     Note that the mounting channel for the fins also has
                                                               flanges on both sides to act as the perimeter trim for the
NOTE: that the light fittings are a slightly darker grey (RAL  next section of ceiling. (The trial of channels with an LED
7039), and the shopfront darker still, (RAL 7043). This is     recess is now discontinued.)
intentional.
                                                               The Contractor is to ensure sufficient support
 Tile Armstrong (Orcal) Metal Lay-In Tile,                     is provided to the suspended ceiling to carry
          Board Edge – Product Number BP9334M                  the self weight plus the increased lighting load,
          Colour: Painted in RAL 7037                          pattresses, etc, and any other services, grilles, or
                                                               louvres.
 Grid Armstrong Prelude 24mm XL2
          Peakform Main Runner – 3600mm2                       Ductwork and mechanical plant, etc, installed
          Armstrong Prelude 24mm XL2 Cross Tee’s               above the suspended ceiling must be
          600mm                                                independently supported, and must not impose
          Colour, all special RAL 7037                         any additional load on the suspended ceiling.

The suspended ceiling must be set out to ensure                At the point where the fresh air duct goes
that the face of the menu board bulkhead (see                  through to outside air (this is normally adjacent
section 2.5.5) is set nominally 1100mm back from               to the rear wall), there will be a filter box built
the front (customer side) face of the counter.                 into the duct. This box will have one removable
                                                               side to allow the filter to be changed. The ceiling
The project drawings will include a reflected                  grid must be arranged so that this filter box is
ceiling plan. This is for general guidance only.               easily accessible through a tile, and without the
The standard setting out dimensions should take                grid obstructing access. If necessary it will be
preference in the event of discrepancies (see                  acceptable to modify the grid at this point to
section 5.3 standard drawing ref. MAN-032)                     accept a 1200 x 600 tile (or thin white laminated
                                                               board), cut if required.
Once this feature bulkhead position is fixed, the
suspended ceiling should be installed, running                 NOTE: This assumes that it is located in a white ceiling tiled
both forward and back, for two full ceiling tiles              area. If it needs to be in the grey ceiling tile area then
before installation of a further feature fin. This             Domino’s PM /Property Dept MUST be consulted.
pattern then continues to the shopfront and to
the back of the kitchen.

NOTE: that the metal tiles are thin and unable to support
suspended fittings.

2.5.2  Suspended Ceilings                                      3 February 2016
   26   27   28   29   30   31   32   33   34   35   36