2.5.4 Window Bulkhead                             2.5.5 Menuboard Downstand Bulkhead

Where a shopfront window head is higher than      The downstand should be installed with the
the nominal suspended ceiling line dictated by    vertical front face nominally set 1100mm back
beams or other obstructions, then the difference  from the front (customer side) face of the
in height must be made up using the ceiling fin   counter. This applies whatever the reflected
material as a bulkhead. Bulkheads must be         ceiling plan may show, unless there is a physical
set back a minimum of 1200mm from the             site reason for variance, or a specific instruction
shopfront line.                                   on a particular project.

                                                  It must have at least 2000mm clearance to the
                                                  underside (preferably 2100mm) and this will
                                                  require an available suspended ceiling height
                                                  of at least 2500mm AFFL. If this is not available
                                                  then the Project Manager and Design Manager
                                                  MUST be informed at the earliest possible
                                                  moment because there may not be enough
                                                  space to install monitors. The area immediately
                                                  behind the screens will protrude down to give
                                                  support to the monitor brackets but should be
                                                  40-50mm smaller all round so that it is not visible
                                                  from the counter.

                                                  See section 5.3 Standard Drawings, drawing no. ‘MAN–

                                                  032 Ceiling Fin and Downstand Limits’ and ‘MAN-33 Menu

                                                  Screen Downstand and Wiring’ for full positioning and

                                                  setting out information

                                                  The downstand can either be supplied by the
                                                  Joinery manufacturer in ‘flat pack’ form for site
                                                  assembly and installation, or it may be fabricated
                                                  on site to achieve exactly the same finished
                                                  result. The bulkhead and all associated fixings
                                                  must be specified to accept a dead load of at
                                                  least 80Kg for 3No. Menu screens. The section
                                                  behind the monitors (ONLY) should be made
                                                  deeper to provide support and protection.

                                                  NOTE: the three 32”monitors are each H = 500mm W =
                                                  760mm D = 70mm and should be mounted so that there is
                                                  no visible gap between them ( The mounting brackets are
                                                  adjustable to allow for this).