•	 Terminate telephone extension lines. The            UK “Self-build” franchisees will need to speak to
    standard is: 4No. on the counter, 1No.             their alarm and phone system companies and
    at drivers table (If the shop is ready, fix        make them aware of this. This does not affect
    handset(s) on the wall as required. If the         ROI stores
    shop is not ready, then turn the back plate        	 A Toshiba system should be programmed
    round on the phone ready for the shopfitters       as standard to operate as follows:
    to fix on the wall), 1No. in office, 2No. “wiring  Pick Handset UP
    only” positions, wall mounted (location will       Dial 9 for a line, then dial the required number
    vary).                                             Wait for a few seconds,
                                                       – Phone display will then say, “Enter Account
If the counter is small, the number of extensions      Code now” Dial the A/C code, which is: 1 9 7 1
on the counter will reduce from 4 to 3No. or in        Phone will then automatically continue to dial
very exceptional circumstances, 2No. If there          the number which was previously entered.
are less than 4 handsets on the counter, there
will be additional wall mounted handsets to            Other system manufacturers may be different
compensate.                                            but should be programmed to achieve a similar
                                                       result.
There may be additional lines to terminate if a
larger system is installed.                            Domino’s Pizza Caller ID Cable Installation Guide
The number of phones on the counter is normally        For a standard system, the site electricians will
governed by the number of bays within the              run two CAT5 data cables for Caller ID. These
counter, and there is always one handset in            cables are to be left coiled in the ceiling near to
each counter bay ( excluding the “disabled/            the BT DP box, at one end, and then run to the
COLLECT” bay).                                         office computer cabinet and terminated with
                                                       RJ45 sockets by the site electrician, at the other
•	 Connect the previously laid in cables for           end.
    the Caller ID, to the telephone system – see       These two cables need punching down into the
    below for ‘punch-down’ details.                    NTTP box by the telephone engineer, as follows:
                                                       First cable:
•	 Leave telephone system programmed and               •	 Line 1, orange and white & orange.
    tested - if the site is not ready for the phones   •	 Line 2, green and white & green.
    to go out, they should be left in a box in the     •	 Line 3, blue and white & blue.
    office or other secure location.                   •	 Line 4, brown and white & brown

•	 Most UK stores are now automatically part of        Second cable:
    a “BT Featureline” package. As a result, an        •	 Line 5, orange and white & orange.
    additional “9” needs to be programmed into         •	 Line 6, green and white & green.
    phone systems and alarm systems to enable          •	 Line 7, blue and white & blue.
    connection to the BT Featureline network.          •	 Line 8, brown and white & brown