Page 75 - B8773-AEW-XX-XX-PP-A-0001_[P1]_Contractors Manual
P. 75
4.4.5 Security System Main contractor to supply and install power
supplies for the security alarm as necessary,
A security alarm system is mandatory for all including a 13A fused spur above the drivers
stores. door for an electrically operated lock.
The system shall be designed, supplied and Access Control – The pizza delivery drivers door
installed by a NACOSS approved alarm installer. must have access control. This will normally be
A typical installation will include the following a door secured by an electro-magnetic lock
items but may vary as recommended by the or some other form of electrically operated
specialist contractor and MUST always comply locking device. As standard, it should be
with the latest ACPO requirements, including released from the inside by a robust push button
dual signaling and dual activation for police and from the outside by a proximity reader and
response. programmable key fobs or similar device.
NOTE: the comment in the phone system section (above) It is essential that the lock ‘fails safe’ and
regarding the need for an extra “9” to be programmed into releases automatically in the event of a fire
the communication system to connect to BT Featureline. alarm activation.
• single reed magnetic contacts to the front The driver’s door must have an automatic closer
and rear doors, fitted and this must be correctly adjusted to
ensure proper locking without either excessive
• passive infra red detectors to the customer banging or time delay
area, office and rear corridor,
• personal attack buttons to the customer
service counter and office
• control panel and keypad in the office
• Redcare or approved alternative signalling
• Final Exit keypad at nominated door.
4.4.5 Security System 3 February 2016