          C2.2 Installation of Pedestrian Barriers

          Safety barriers shall  be set out as indicated         In order to assist the setting out of posts and fixing
          on  the designer’s  detail patio layout with all       of the datum level, the principal  contractor
          panels bolted between fixed position posts. All        may find that shims between the mass concrete
          standard barriers are 1500mm and 600mm long            foundation and the underside of the post is the
          from centres of post.                                  most  simple  method  of  fixing  the  datum  level.
                                                                 Shims must be galvanised mild steel, footprint at
          There  is a choice of two posts. One post is a         least equal to the size and format as the post
          standard low level post, the other is a high post      base.
          with lamp head. All posts are hollow; this allows
          an  electrical feed  to  be  pulled through  the       Once foundations have cured, each post must
          centre for the posts with lamp heads. The type         then be bolt fixed to the corresponding concrete
          of post is distinguished on the designer’s patio       pad foundation using 4No bolts to each post,
          detail drawings in each location.                      provided by the manufacturer.


          Infill  panels  are  fitted  between  the  posts  via   Once the posts are in position, the panels are
          brackets provided which must be riveted to the         fixed in position via 2No bolt connections to each
          posts by the principal contractor. All panels must     post using the locations and bolts provided.
          be  set  along  the  same  datum  line in  relation
          to  ground  level. Assessing  the  levels on  site,  a   Excavations around  post foundations  should
          patio datum line must be established to ensure         be backfilled and finishes reinstated to suit the
          the greatest number  of top rails on the safety        specified surface finish.
          barriers are 1100mm above local finished patio
          level. This will be referred to as the patio setting
          out datum level.


          Once the position of posts have been set out and
          the  patio  setting  out  datum  level established,
          mass concrete  foundations  of  approx  400x
          400x400 for low posts and 600x600x600 for high
          posts should be poured with a finished pad level
          -150mm below the patio finish datum level. For
          high level posts with lamp heads a duct route
          must be cast into the concrete foundation for
          an electrical feed to the lamp head.
















           C2.2           Installation of Pedestrian Barriers  1.0                       08 October 2014
   272   273   274   275   276   277   278   279   280   281   282