Page 280 - B6118-AEW-XX-XX-PP-A-0001_(P16)_Contractors Manual
P. 280

CONSTRUCT





        C2 External Works






        C2.4 Installation of Tactile Paving

        400x400mm  Marshall’s blister (tactile) paving
        should be installed at designated pedestrian
        crossing  points,  identified  on  the  designer’s
        proposed site plan.

        Tactile paving must be set out in the direction
        of travel of the  crossing and not  necessarily
        perpendicular to  the  kerbline.  The  tactile
        paving must  provide a  colour  contrast  to  the
        surrounding  surface  finish  and  be  laid  in  two
        rows of three paviors with a central third line of
        two paviors as shown.






















































         C2.4           Installation of Tactile Paving      1.0                        08 October 2014