Page 101 - (KU)01-75GAJ-1.5 - Change 1
P. 101

INTRO


   EP'S                                                              (KU)01-75GAJ-1.5                 A     FIGURES


                                                  1.2.2 CAUTIONS                                      B
                                                                                                             ACAWS
                                    Alert/Condition                    Crew Action
                              TK 1 (2, 3 or 4) HEAVY                                                  C     GROUND
                              Fuel quantity difference of   Fuel balance.............................. Restore
                              more than 1,000 pounds exists                                           D
                              between symmetrical main          Use Transfer, CROSS FEED and
                              tanks. The tank that is heavier   CROSS SHIP switches as required             TAKEOFF
                              will be annunciated.              to burn fuel equally.                 E
                              TK 1 (or 4) XFER PMP FAIL                                                     FIRE/SMK
  NORM                        The FMC has detected a failure   If fuel quantity is less than or equal   F
                              of the respective transfer pump
                                                            to 1,520 pounds in Àight or less
                              due to low current draw. This   than or equal to 1,900 pounds on              PRES/OXY
                              can occur if the fuel level falls   the ground:                        G
                              below the pump inlet.
                                                            Transfer FROM switch (affected pump)...
                                                            ...................................................... OFF  H  ENG/PROP

                                                            If fuel quantity exceeds the above
                                                            values:                                   I        FUEL
                                                            CROSS FEED switches (all)...... CLSD

                                                            CROSS SHIP switch................... Open  L
                                                                                                               AAR
                                                            Transfer FROM switches (all except
                                                            affected pump).............................. OFF  M
  SPEC                              NOT FOR FLIGHT                                                             ELEC
                                                            Transfer TO switches................. CLSD
                                                            Pump pressure............................ Verify  N

                                                            If pump pressure is less than 23 psi:              HYD
                                                                                                     O
                                                            Tank 1 (or 4) transfer pump............. Off
                                                            TK 1 (or 4) XFER PUMP ECB (affected             FLT CTRL
                                                            pump).......................................... PULL  P
                                                                TK 1 XFER PUMP ECB (219)
                                                                                                      R       GEAR
                                                                TK 4 XFER PUMP ECB (222)

                                                                Do not turn the pump on or reset
                                                                the ECB until proper inspection       S     DOR/RMP
  PERF                                                          and repairs have been performed.

                                                            Alternate Fuel Management procedure...    T     JETTISON
                                                            ........................................... Accomplish

                                                            If the ACAWS clears and affected          U
                                                            pump pressure is greater than or                LANDING
                                                            equal to 23 psi:
                                                                                                      V
                                                            Continue pump operation.
                                                                                                            DITCHING
                                                                                                     W
                                                                                                            BAILOUT
                                                                                                      X

  OPER                                                                                                      FAULT LG

                                                              -
                            Use, copying and/or disclosure is   181
                            governed by the statement on the
                            title page of this document.  BACK                                               CHARTS
   96   97   98   99   100   101   102   103   104   105   106