Page 1002 - CRESTRON HOME OS-3
P. 1002

Set up using a Security System Keypad

               NOTE: The following procedure was created using the Premier Elite 48 security system.


                   1.  Assign Crestron System to COM2:
                         a.  Enter 1,2, 3, 4 to log in as engineer.
                         b.  Select 7 UDL/Digi and then YES.

                         c.  Select 8 Com Port Setup and then YES.

                         d.  Use the arrow keys to select Com Port 2.
                         e.  To change the setting, select NO.

                         f.  Use the arrow keys to cycle through the available options. Select Crestron System
                           and then YES to confirm.

                         g.  Press MENU, MENU, MENU, and then YES to log out of engineers mode.
                   2.  Assign 19200 for the BAUD RATE:

                         a.  Enter 1, 2, 3, 4 to log in as engineer.
                         b.  Select 7 UDL/Digi and then Yes.

                         c.  Select 7 Setup Modules and then YES.

                         d.  Select 9 Modem Speed and then YES.
                         e.  To change the speed, select NO.

                         f.  Use the up and down arrows to select the speed. Select 19200 and then YES.

                           NOTE: The keypad may display some com traffic. This is normal.

                         g.  Press MENU, MENU, MENU, and then YES to log out of engineers mode.































                Product Manual — Doc. 8525Z                                             Crestron Home™ OS • 985
   997   998   999   1000   1001   1002   1003   1004   1005   1006   1007