Page 998 - CRESTRON HOME OS-3
P. 998
Interlogix Security System
The Interlogix security system must be configured to work with the Crestron Home system.
NOTE: The Interlogix NX-587e virtual keypad module is required in order to use Crestron Home
system with an Interlogix security system .
Models
The following models are supported:
l NetworX NX-4
l NetworX NX-4V2
l NetworX NX-6
l NetworX NX-6V2
l NetworX NX-8
l NetworX NX-8E
l NetworX NX-8V2
NOTE: The systems listed above support keypad emulation. They do not support an area list for
systems that support areas, area control to arm or disarm the system (including storing the
password on the UI device), programming area arm or disarm events, and triggering area
commands from button or trigger events via scenes.
Wiring
The Honeywell 4232CBM interface card should be connected to the Crestron Home system as
shown below:
NOTE: The serial port is configured to communicate at 9,600 baud, 8 data bits, 1 stop bit, and
no parity. There is no hardware or software flow control.
Crestron Home System Interlogix NX-587e (DB9F)
GND Pin 5
TX Pin 2
RX Pin 3
The Interlogix NX-587e requires a RJ-14 (6-pin) telco cable to tie the adapter into the control
panel.
RJ-14 (6-Pin) Interlogix Control Panel Keypad Connection
GND Pin 5
TX Pin 2
RX Pin 3
Product Manual — Doc. 8525Z Crestron Home™ OS • 981